Prices  54733-C2868  Berthold  Germany

BRAND Berthold
Product 54733-C2868
Description Level Measurement
Internal code IMP4879835
Custom code 78060080
Technical specification CrystalSENS LB 480, Nal 50/50, with water cooling Power supply: 100 - 240VAC, 50 - 60 Hz HART master detector, HART 7 compatible Locations ATEX (Europa): II 2G, Il 2D Locations NEC (U.S.A.) / CEC (Canada): Class | Zone 1, Zone 21 Markings ATEX / IECEx / CEC: Gas: Ex db eb lIC T6 Gb Dust: Ex tb IIIC T95 °C Db Markings NEC: Gas: AEx db eb IC T6 Gb Dust: AEx tb IIICT95 °C Db Ambient Temp. Té: -40°C... #65 °C T1-T5:-40°C ... +80 °C above 60°C water cooling required Signal output: 4 ... 20 mA, isolated, self monitoring Protection: IP66, IP67, IP68, IP69K, Nema 4X, Nema 6 Current output: active Digital output: open collector for signalling Error, Min/Max-Alarm, Det.-Temp., Rad.-Interf. Collimator: axial with water cooling Automatic decay compensation Self monitoring Menu-guided setup via HART Cable entry radial M20 Licence Key 2 for Level Switch and Level Housing: stainless steel 1.4301 (304)

Berthold - 54733-C2868 referenced Level Measurement product produced by high technology.
54733-C2868 became irreplaceable of foundations. 54733-C2868 referenced product which is satisfy the customer's needs, offers advantages of quality and cost. It produced result of tests of laborotory for years. Contact us if you are looking for alternative price of 54733-C2868 .

Sales Offices!

Press on flag images to see contact information!