BRAND | Boll Kirch |
Product | 6.72 Gr 04 DN 40 |
Internal code | IMP4884765 |
Custom code | 842199 |
Technical specification | Filter type 6.72TI1 Size 04TI1 Nominal connection size DN 40TI1 WN165 connection flanges, TI1 square flanges Dimension sheet Z120291TI1 TIU2 --- OPERATING CONDITIONS --- DieselOilTI1 fluid to be filtered Fluid group in accordance with PED 1TI1 Fluid type according to PED liquidTI1 Operating pressure 6.00 bARTi1 Maximum allowable pressure 10.00 barTi1 Permit Operating temperature min 0.00 °CTI1 Permit Operating temperature max 100.00 °CTI1 TIU2 --- BACKWASH --- Clean/dry air backwash medium max.4barTI1 Flushing time 8 stI1 Air control medium 4-10bar ISO 8573-1:2010 (7/4/4) TI1 Flushing volume per chamber and flush 3.20 litresTi1 Purge air requirement per rinse 0.010 Nm³Ti1 Operating voltage 3 ph 400 voltTi1 Frequency 50 HzTi1 Control voltage 230 volts Control without TI1 PP3 flushing interval forced flushing 30 min -- DESIGN/APPROVAL --- Design and design PED2014/68/EU AD-2000TI1 Article 4, Paragraph 3TI1 Volume of the container 7.40 litresI1 Empty weight 95 kgTi1 Pressure test according to Boll & Kirch with attestTI1 Material certificates EN 10204/3.1TI1 PP3 empty weight 95 kg TIU2 --- MATERIALS --- Filter housing made of EN-GJS-400-15TI1 Viton GF-STI1 gasket Seals made of Viton GF-STI1 TIU2 --- FILTER ELEMENTS --- Element type fabric core candleZeti1 Number of filter elements 2TI1 No. of filter elements per chamber 1TI1 Number of filter chambers 2TI1 Candle head and end piece made of stainless steel Ti1 1.4401TI1 fabric Filter fineness 3 μMTi1 Sieve area in operation 2400 cm²Ti1 Total sieve area 4800 cm² ACCESSORIES --- Heated steam filter housing TI1 Permissible Operating pressure in the boiler room 14.00 bARTi1 Permissible Operating temperature in the boiler room 200.00 °CTI1 Attached differential pressure indicator 4.36.2 (optical + electrical) TI1 Viton GF-STI1 differential pressure indicator sealant Differential pressure settings backwash 0.38 bar/alarm 0.50 barTi1 Counterflan. Screws and gaskets includeTI1 PP3 heating is not connected with diesel --- Accessories/differential pressure measurement---CAT DDA with shut-off hoodTI1 TIU2 --- CORROSION PROTECTION --- Exterior primer 2K-Ep RAL 9010TI1 Internal preservation of hydraulic oil ISO VG 32TI1 TIU2 --- IDENTIFICATION --- Operating/factory label German/EnglishTI1 Labelling after TI1 TIU2 --- DOCUMENTATION --- Language of the operating instructions in German/English Operating manual 1x PDFTi1 Approval certificates/certificate 1x pdfTi1 Declaration of conformity included |
Press on flag images to see contact information!