Free vent - deflagration and endurance burning proof PROTEGO® BE/HZ-25-IIA protective system with EC-Type Examination Certificate as per data sheet: BE_HZ_KA_2_GB.pdf pipe inner thread connection: G1" nominal pressure of housing PN 1 housing module lower part of housing: 1.4408 upper part of housing: 1.4408 weather hood: acrylic glass bolts: A2 FLAMEFILTER® set - 2fold: 1.4571 FLAMEFILTER® gap: 0,5 mm Standard: EN 12874 Type examination certificate No.: PTB00ATEX4095X Explosion Group: IIA MESG: > 0,90 mm Max. Operating Temperature: 60° C
FLAME ARRESTER UNIT For PROTEGO BE/HK-50-IIA
Detonation arrester - for stable detonations PROTEGO® DR / ES-15 IIB3-P1,2.Schutzsystem with EC-Type Examination Certificate Pipe thread connections: G1 / 2 " housing assembly Housing: 1.0619 A bumper: 1.0619 Sealing: PTFE Screws / nuts A2 FLAMEFILTER® set - 3x: 1.4571 FLAMEFILTER® gap width: 0.7 mm EC Baumusterprüfbesch. No .: IBExU03ATEX2002X Explosion group: IIB3 MESG:> = 0.65 mm .. Maximum permissible operating temperature: 60 ° C Max. Permissible operating pressure. 1.2 bar abs.
Detonation arrester - for stable detonations PROTEGO® DR / ES-50-IIA-P 1,2 Protection system EC-Type Examination Certificate after foliar: DR_ES_25_bis_200_KA_4_D.pdf Flange DN: 50 drilled according to DIN 2501, PN: 16 form C housing assembly Housing: 1.4408 A bumper: 1.4408 O-ring: PTFE Screws / nuts A2 PROTEGO® flame arrester FLAMEFILTER® cage: 1.4408 FLAMEFILTER® set - 3x: 1.4571 FLAMEFILTER® gap width: 0.9 mm Liner: 1.4571 Screws / nuts: A4 EC Baumusterprüfbesch. No .: IBExU11ATEX2007X Explosion group: IIA MESG:> 0.90 mm .. Maximum permissible operating temperature: 60 ° C Max. Permissible operating pressure. 1.2 bar abs.
(Detonation arrester - acting on both sides PROTEGO® DA-G-1 "-IIB3-P 1,1 Protection system EC-Type Examination Certificate after foliar: DA_G_KA_4_D.pdf Pipe thread connections: G1 " housing assembly Housing: 1.4408 Cage tube: 1.4408 Sealing: PTFE Screws: A2 FLAMEFILTER® set - 5x: 1.4571 FLAMEFILTER® gap width: 0.5 mm EC Baumusterprüfbesch. No .: IBExU10ATEX2148X Explosion group: IIB3 MESG:> = 0.65 mm .. Maximum permissible operating temperature: 60 ° C Max. Permissible operating pressure. Bar abs 1.1. Product number: 84798997 Country of origin: Germany Piece weight ca.2,9 KG)
fusible element 316 ss/1.4571 for BE/HK-50-IIA
FLAMEFILTER SET
JOİNT BOLT:316 SS/1.4571
ARTICLE :322220023 FLAME ARRESTER UNIT For PROTEGO DR/ES-T-150-IIA
Free vent - deflagration proof PROTEGO® BE/AD-25-IIB3 protective system with EC-Type Examination Certificate as per data sheet: BE_AD_KA_2_GB.pdf pipe inner thread connection: G 1" nominal pressure of housing PN 1 housing module housing: 1.4408 weather hood: stainless steel bolts: A4 FLAMEFILTER®: 1.4571 FLAMEFILTER® gap: 0,9 mm Type examination certificate No.: IBExU03ATEX2200X Explosion Group: IIB3 MESG: >= 0,65 mm Max. Operating Temperature: 60° C
PROTEGO® BE/AD-25-IIC protective system with EC-Type Examination Certificate as per data sheet: BE_AD_KA_2_GB.pdf pipe inner thread connection: G 1" nominal pressure of housing PN 1 housing module housing: 1.4408 weather hood: stainless steel bolts: A4 FLAMEFILTER®: 1.4571 FLAMEFILTER® gap: 0,2 mm Type examination certificate No.: IBExU03ATEX2201X Explosion Group: IIC MESG: < 0,50 mm Max. Operating Temperature: 60° C
LEG SPRING:1.4310
RETAİNİNG ring 1.4034 for BE/HK-50-IIA
flame filter
Set pressure: + 18,00 mbar Volume flow at design pressure: 324 m³ / h Design pressure: + 20,00 mbar Set pressure: - 9.00 mbar Volume flow at design pressure: 204 m³ / h Design pressure: - 10.00 mbar Pressure and vacuum relief valve - deflagration and endurance burning PROTEGO® PV / EBR-80-IIA Protection system EC-Type Examination Certificate after foliar: PV_EBR_KA_7_D.pdf Flange DN: 80 drilled according to DIN 2501, PN: 16 form C Housing pressure PN 1 Conformity to 94/9 / EC
Material: 1.4310 Gap width: 0.7 mm for PROTEGO® DR / EU-40 IIA P1,6 FLAMEFILTER® set for PROTEGO® fittings When installing the FLAMEFILTER® is absolutely our operating instructions observed. FLAMEFILTER® set FLAMEFILTER® set - 3x: 1.4310 FLAMEFILTER® gap width: 0.7 mm Liner: 1.4571
Material: 1.4310 Gap width: 0.5 mm for PROTEGO® DA-UB-300/150 IIB3-P1,3-X3 set FLAMEFILTER® for PROTEGO® fittings When installing the FLAMEFILTER® is absolutely our operating instructions observed. FLAMEFILTER® set FLAMEFILTER® set - 7x: 1.4310 FLAMEFILTER® gap width: 0.5 mm Liners: 1.4571
poetry for PROTEGO® fittings poetry Sealing: PTFE
O-ring seal for PROTEGO® fittings O-ring seal O-ring: FPM
FREE VENT DEFLAGRATION AND ENDURANCE BURNING PROOF
for 2-EHA, Methyl Acrylate and Methyl Metacrylate service Set Pressure :+10mbar Material :1,4408
IN LINE DETONATION FLAME ARRESTER
Detonation-Proof Foot Valve
stainless steel DN50
Detonation arrester
Valve deflagration and endurance burning prOOF Pressure :+30mbar Set Pressure :-10mbar Material :1,4408
Works certificate WAZ DIN / EN 10204/3.1 issued by Brunswick FLAMEFILTER
(According to DIN / EN 10204 / 3.1 issued by BRAUNSCHWEIGER FLAMES FILTER with exams after PROTEGO® factory specification, e.g. Function control and adjustment pressure (in valves) and the Materials used aufzeigend - but without material analyzes per position, net)