BRAND | Regloplas |
Product | REGLOPLAS 150 |
Internal code | IMP4642432 |
Technical specification | Regloplas Model 150/12KW/TP20/1K/RT100 Single Zone Temperature Control Unit Outlet Temperature – Maximum 300 F o Number of Independent Zones 1 o Heat Transfer Fluid Thermal Oil o Filling Capacity of Unit 4.6 Gallons o Expansion/Reservoir Capacity – Maximum 1.6 Gallons o Heating Capacity 12kW o Cooling Capacity at Outlet – Maximum 58kW @ 285º F. o Pump type / HP TP20 / .75 HP o Flow Rate – Maximum 16 GPM o Outlet Pressure – Maximum 55 PSI o Controller Model RT-100 o Measuring Mode – Standard PT-100 o Operating Voltage 480V/3/60 o Control Voltage 230V/1/60 o Power Requirements – Maximum 18 Amps @ 480V o Connections - Oil Outlet/Inlet G ½” o Connections - Water Outlet/Inlet G ½” o Noise level <70db |