BRAND | Rotork |
Product | EA-IQ18-F10-A-24RP |
Description | three phase electric actuator |
Internal code | IMP315626 |
Weight | 1 |
Technical specification | IQ (3rd Generation) MULTI-TURN IQ18 F10 A [IP68] 380/3/50 24RPM (-30 +70 °C) 3x M25/1x M40 101B0000 . • INGRESS PROTECTION: IP66/IP68 - 20 metres/10 days, double-sealed terminal compartment • TEMPERATURE: -30° C to 70° C (-22° F to 158° F) for Watertight, FM or CSA EP enclosures, -20° C to 70° C (-4° F to 158° F) for ATEX or IECEx enclosures • MOTOR: Three phase low inertia squirrel cage motor, class F insulation, incorporating thermostat protection. • SERVICE/DUTY RATING: Class A (On/Off)/Class B (Inching), nominal 60 starts at a rate ≤ 600 starts/hour. 15 minute rated at nominal 33% of rated torque • STARTER: Integral electrically and mechanically interlocked reversing contactors. • DRIVE: Incorporates lost motion ‘hammer-blowʼ, for releasing sticking valves • SYNCROPHASE: Auto Phase rotation correction and lost phase protection • LOCAL CONTROLS: Open/Close selector and padlockable Local/Stop/Remote selector (stop remains available for safety) • LOCAL INDICATION: Integral illuminated, digital valve position indicator showing 0.1% increments in position with closed and open limit symbols, torque, alarms and other status data. 3 LED's; red-open yellow-intermediate, green-closed (can reverse), blinker and alarms configurable. • BATTERY SUPPORT: Battery is not required for position sensing but, supports LCD display, operation of indication relays, commissioning and data logging in absence of mains power • POSITION SENSOR: Absolute encoder with 8000 turn, 0.1% resolution with built in redundancy, provides continuous high resolution position measurement which is fully maintained during manual operation and without mains power or battery support • MOUNTING: Can be in any orientation, local indication and controls rotatable in 90° increments to suit • MANUAL OVERRIDE: Padlockable clutch lever, Handwheel clockwise to close, automatically disengages when motor starts and non-rotating during electric operation • LUBRICATION: Gearcase oil filled for life • TORQUE SWITCHES: Adjustable electronic torque switches 40% to 100% of rated with start of travel bypass option. • COMMISSIONING: Non- intrusive setup of; travel limits (auto setup option), relays, alarms and other functions via Infrared/Bluetooth Setting Tool (one supplied with each order). Can be password protected • DATA LOGGING/ASSET MANAGEMENT: Date/time stamped logging and display of operational events/trends, motor starts and valve torque profiles. Valve/actuator and gearbox data can be stored and service alarms set. Data download via Infrared/Bluetooth Setting Tool for upload to a PC and analysis via free InSight2 software • CABLE ENTRIES: 4 threaded entries Metric, NPT or PG, cable glands not included • TERMINALS: M5 power and M4 control terminals, screws and washers supplied. For ring tag conductors, power 16.0mm², controls 4.0mm² PAINT: Polyester powder coating 100 micron nominal thickness. Colours: Housings/Covers - Grey (00-A-05), Handwheel/Hand Auto Lever/Base – Black . Wiring diagram 101B0000 is described in IQ/IQT Control and Monitoring publication (PUB002-041) and includes: • CONTROL SUPPLY: 20 – 60VDC/40 – 120VAC or actuator derived 24VDC • CONTROL INPUTS: 6 inputs for open, close, stop/maintain, ESD and interlock signals, 20 – 60VDC/40 – 120VAC • INDICATION CONTACTS: 4 volt-free (SPST) latching contacts (S1-S4), rated at 120VAC/30VDC, 5mA to 5A, each configurable NO or NC to signal one of the following; open/closed or intermediate positions, moving (continuous or pulsing), Handwheel operation, local selected, remote selected, open/close interlock active, ESD active, motor tripped on torque in mid travel/going open/going closed, valve jammed, loss of power/phase or control supply, battery low, internal failure detected, thermostat tripped, programmable service alarms. • MONITOR AND AVAILABILITY RELAY: Independent relay with volt-free changeover contact, rated at 120VAC/30VDC, 5mA to 5A. De-energises in case of; loss of power/phase or control supply, local control or local stop selected (can be excluded), motor thermostat tripped or detected internal failure • ANALOGUE FEEDBACK: 4-20mA output proportional to position (CPT), internally powered. |
default.send_request_amp_Group2